Customers & Feedback

  • "Garmin International"
    A. Landis
  • "Napa Auto Parts"
    J. Isabelle
  • "Resco Plastics, Inc."
    W. Zink
  • "National Aviation Academy"
    J. Cupery
  • "US EPA"
    C. Hankins
  • "Penn State University"
    R. Thomas
  • "City of Raleigh Fire Dept."
    C. Joyner
  • "Empire Floors CA"
    C. Misner
  • "National Air of Texas"
    C. Williams
  • "North Pressure Wash"
    J. Yos
  • "Kilroy Insulation"
    S. Johnson
  • "RSM Electron Power, Inc."
    J. Diaz
  • "Alaska Pacific Rental"
    M. Steel
  • "Springhill Medical Center"
    R. Price
  • "Speedy Concrete Cutting"
    T. Barna
  • "C&W Davis Transport"
    C. Davis
  • "Elliot Electric"
    T. Cox
  • "Wickstrom Ford"
    P. Morgan
  • "All Phase Hydraulics"
    J. Truax
  • "National Magnetics Group, Inc."
    D. Flyte
  • "Dakota Battery & Electric"
    K. Rick
  • "PawPrints Pet Salon"
    P. Falco
  • "LM Heavy Civil Construction"
    P. Frew
  • "Century Mold Company"
    R. Manners
  • "Pentair Water"
    A. Cruz
  • "Speed Wrench Inc."
    T. Decker
Secured Checkout

  Home > Oberdorfer Pumps > FIP (Pump Only) >

Oberdorfer FIP Pump Model# 401M-02
Oberdorfer FIP Pump Model# 401M-02
 
List Price: $1,168.15
Our Price: $834.39
You save $333.76!


Availability: In Stock, Usually Ships in 24 Hours
Product Code: 401M-02

Description
 
Oberdorfer FIP Pump Modle# 401M-02

The impeller must be replaced if it is worn out or has been damaged by debris or by running the pump dry. Symptoms of a defective impeller are low pumping pressure and low flow causing overheating of the boat engine. Poor pump performance can also be caused by slippage of V-belts, so belts should be checked for tightness. To replace the impeller remove screws and cover, pull out the impeller with needle nose pliers or two screwdrivers. Be careful not to dent the pumping chamber with these tools. When inserting new impeller, line up key slot in impeller with the key in the shaft. Use oil on shaft and avoid forcing the impeller onto the shaft.

The impeller should also be removed for storage periods to prevent the blades from taking a permanent set.

If water drips from the weep hole or from the area where the shaft exits the pump, the seal is defective and must be replaced. While the Polytetrafluoroethylene (PTFE) barrier seal provides a first line of defense, prolonged running of the pump with a leaky seal can destroy the ball bearings resulting in catastrophic pump failure and engine shut-down. For seal replacement, the pump must be removed from the engine and disassembled in order to gain access to the seal area. Where mechanical seals are used, both components (stationary and rotating member) must be replaced at the same time. Lip seals must be pushed out of their press-fitted position and new seals pressed into place, using a sealant on the outside of the lip seal housing. Refer to exploded view drawings for seal location and part numbers for ordering purposes.

FEATURES

  • Bronze Construction - Corrosion Resistance
  • Large Suction and Discharge Ports
  • Polytetrafluoroethylene (PTFE) Barrier Seals Protecting Ball Bearings
  • Mechanical Carbon Ring, Ceramic Face Main Pump Seal Standard
  • Two Sealed Ball Bearings Spaced for Maximum Load Ability
  • Large Vent & Drain Openings Separate Seal & Bearing Areas
  • Shaft Slinger for Additional Bearing Protection
  • Neoprene Impeller Standard, Nitrile Impeller Optional (Both are Spline Drive)
  • High Chrome Nickel Stainless Steel Shaft
  • Extra Capacity Ball Bearings plus Rugged Construction for Prolonged Service Life
  • Impeller Easily Replaced
  • Machined in Cam
  • Nitrile O-ring Between Body and Cover Eliminates Gasket Problems
  • Electric Clutch Options

DRIVE

Either direct drive with flexible coupling or pulley drive can be used. Make sure both flexible coupling halves are properly aligned. When using pulley, do not over-tighten belt.

Direction of shaft rotation determines inlet and outlet ports. (see line drawing)

Pump will operate satisfactorily when mounted in any position. DO NOT RUN DRY. Rubber impeller pumps generate high rubbing friction unless lubricated by liquid pumped. Lack of liquid will cause impeller to burn up.

LIQUIDS & TEMPERATURES

Liquids compatible with neoprene can be pumped including fresh and salt-water solutions and mild chemicals. Do not pump severe solvents or acids. When possible, flush the pump with fresh water after each usage. Nitrile impellers can handle oil-contaminated water and kerosene at reduced impeller service life.

Extremes of cold and heat will affect impeller life. Limits of 40o to 180o F should be observed. Do not allow liquid in pump to freeze. Drain pump by loosening cover screws. Use methyl alcohol based anti-freeze compounds such as Zerex, Shell Zone, Pyro Permanent, Permagard, or Dowgard.

SUCTION LIFT

Suction lift of 15 feet is possible when impeller is wet. Suction lines must be air tight in order for pump to self-prime. A foot valve at beginning of suction line is recommended.




Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Oberdorfer Pumps > FIP (Pump Only)